Column and Beam Drywall Clip, (60/box)
Item Number: CB60
CB60 Column and Beam Drywall Clip - the fastest, easiest, most cost-efficient, UL Classified way to add fire resistance to steel columns and beams.

CB60 Column and Beam Drywall Clip - the fastest, easiest, most cost-efficient, UL Classified way to add fire resistance to steel columns and beams.
Specifications
Coating:Hot-Dip Galvanized
Min. Tensile Strength:39 ksi
Min. Yield Strength:33 ksi
Packaging Type:Box
Material Thickness:0.0180 in.
Â
- Fast and convenient way to wrap columns and beams for fire-resistance requirements.
- Clips are hand applied and friction fit for easy installation.
- Fewer materials required and fast installation offers significant labor and material savings.
- Large flat surface area for easy fastener penetration and to accept multiple fasteners if needed.
The clip complies with ASTM A653 and A1003 performance requirements.
Â
These are basic installation guidelines. Please see the CB60 Column and Beam Drywall Clip document for detailed installation instructions for the multiple UL Fire-resistive assemblies that utilize the CB60 clip. Slide the CB60 clip onto the flanges of the column or beam.
- Trim the first layer of gypsum board to the outside edge of the CB60 clip.
- Gypsum board will be cut and positioned such that only one joint terminates at any outside corner, with the subsequent layer overlapping the underlying joint.
- Attach the gypsum board with Grabber Type S screws.
- Finish the assembly with the specified type, thickness and layers of gypsum board, corner bead, and joint compound.
Attachment device to secure gypsum board and sheathing to achieve the fire-resistance requirements for column and beam structural members.
©2025 The trademarks Grabber, PanelMax and Stylized G on Grabber Fasteners, are trademarks of Grabber Construction Products, Inc. Underwriters Laboratories (UL), iQ, Prospector, the UL logo and the UL mark are registered trademarks of UL, LLC. UL fire-resistance-rated designs are published by UL, LLC and referenced here for informational and compliance purposes. Use of UL design assemblies does not imply UL certification or endorsement.
1 Hour Column: X528
2 Hour Column: X517, X520, X523, X528, X535
3 Hour Column: X513, X528, X535
4 Hour Column: X522, X535
2 Hour Beam: N501, N502
3 Hour Beam: N505
CB60 Column and Beam Drywall Clip - the fastest, easiest, most cost-efficient, UL Classified way to add fire resistance to steel columns and beams.
Specifications
Coating:Hot-Dip Galvanized
Min. Tensile Strength:39 ksi
Min. Yield Strength:33 ksi
Packaging Type:Box
Material Thickness:0.0180 in.
Gauge:25 MSG
Size:2 3/8 in. x 2 in. x 2 1/2 in.
Amount:60
Weight:2.9 oz.